The outer part of the stationary system for supplying water to a private house is usually placed in the thickness of the soil. So it does not occupy a place on the site, it is protected from mechanical influences. However, it must be protected from low temperatures during the frosty period. What to do to exclude the formation of traffic jams in the pipeline in winter?
For uninterrupted water supply in the winter, it is necessary to carry out insulation of the water supply in the ground. We will tell you how to protect pipes laid in the ground from freezing. The article presented for acquaintance describes in detail the tested in practice options for solving this problem.
Rules for the construction of underground water
Freezing of the underground water supply occurs due to the achievement of soil temperature of negative values. One way to prevent this from happening is to hold pipes at a depth where sub-zero temperatures are unattainable.
If this requirement has not been met, other measures must be taken to solve the problem of uninterrupted water supply.
Image Gallery
Photo from
A water pipe laid in the ground is insulated if it is laid above the level of seasonal freezing of soils. The area from the freezing point to the entrance to the heated room is insulated in any case
To lay pipelines above the freezing level, ready-made heat-insulating systems with corrugated waterproofing shell are produced
To assemble underground sections of water pipes, pipes are made with a polyurethane foam outer protective layer that protects the system from freezing, and pipes from corrosion
The use of insulating foam shells is acceptable. However, it must have a strong and sufficiently powerful waterproofing outer layer, because polystyrene is able to absorb and pass water through the pores
The tasks of hydro and thermal insulation are excellently solved by the sprayed polyurethane foam, which can be applied after the plumbing device
In case of insulation of underground water supply lines with thermal insulation capable of absorbing water, laying is allowed only in boxes or protective covers
If the entire water main is laid above the level of seasonal freezing, it is completely insulated from the water intake point to the entrance to the heated room
In the casing device for pipes insulated with absorbent material, factory-made ducts, sheet steel, roofing material or larger pipes are used
Depth of thermal insulation of the water supply
Ready-made system of insulated piping
Polyurethane protective shell for pipes
Insulating foam shell
Symbiosis of hydro and thermal insulation
Laying insulated pipes in the box
Thermal insulation at the outlet of the caisson
Option insulating klzhuha
The main provisions of regulatory documents
According to paragraph 11.40 of the set of rules SP 31.13330.2012, the depth of the laid pipes, counting to the bottom, should be 0.5 meters more than the estimated depth of penetration of zero temperature into the ground. This is necessary to prevent the formation of ice plugs in the pipeline and rupture of pipes in places of crystallization of water, which increases with freezing in volume.
The estimated depth, according to paragraph 11.41 of the same rules, should be established by field observations of the contour of freezing soil, as well as be guided by the experience of operating pipelines in this area.
Such information may be owned by the hydrometeorological center or water supply organizations. In the absence of field data, it is necessary to determine the depth of thermal engineering calculations.
As a result of freezing of the water supply pipe often breaks. If they are located in the ground, their replacement will take a long time.
According to paragraph 5.5.3 of the set of rules SP 22.13330.2011, the normative depth of seasonal freezing of the soil in the absence of long-term observation data must be determined on the basis of thermal engineering calculations presented in the figure below.
The values of the average monthly air temperature in the settlements of the constituent entities of the Russian Federation should be taken from table 5.1 of the code of rules SP 131.13330.2012.
The value of the estimated normative depth of seasonal freezing of soils depends on their type and climatic features of the cold period for this territory
In case of exceeding the obtained value of 2.5 meters, as well as for mountainous areas with a sharp change in the terrain, climatic or engineering-geological conditions, it is necessary to determine the standard depth of soil freezing according to the formulas in Appendix “G” of the code of rules SP 25.13330.2012.
The estimated freezing depth according to paragraph 5.5.4 of the set of rules of the joint venture 22.13330.2011 for areas with non-negative average annual temperature values is determined by multiplying the standard value by a factor of 1.1. For territories with negative values, this value is calculated according to SP 25.13330.2012.
Low temperature protection
It is not always possible to completely or partially lay the water supply system below the zero isotherm. Sometimes this cannot be done for technical reasons, for example, when the outlet of the water pipe from the well is above the boundary of the freezing zone of the earth.
The freezing level mark is determined in accordance with the climatic specifics of the region in which the water supply is being built.
For the middle strip, this value is 1.0 - 1.3 m depending on the type of soil, in areas with severe winters, the depth of pipe placement, according to the rules, will be more than 2.0 - 2.5 meters, which is very expensive as when laying, and in case of need of repair.
In areas with cold and long winters, the depth of the trench for laying the water supply can be more than 2.0 - 2.5 meters, depending on the type of soil in which the pipeline is laid
If it is impossible or expensive to place the water supply at a great depth, other measures are used for its smooth operation. They can be divided into two categories:
- Warming. Designed to reduce heat loss by an object per unit of time. It is carried out using materials having low thermal conductivity.
- Heating. Designed to increase the temperature of the object. To implement this procedure, an external source of thermal energy is required.
The choice of the option of warming or heating the external branch of the water supply depends on the operating conditions, temperature conditions, the geometry of the system, the simplicity of the work performed, as well as the efficiency, cost and reliability of the way to solve the problem.
Ways of insulation of external water supply
There are many ways to warm a street water supply system located in the ground. If only cold water is supplied, then due to a small temperature difference, the thermal conductivity of the materials used is not as important as their durability, strength or price.
For hot water supplied to the country house with a centralized network, ground tracks are insulated. Due to the large temperature difference between hot water and the environment, the thermal conductivity of the material is given great attention
Application of simple techniques
In the event that the pipes are located practically on the border of the freezing zone, then to eliminate the likelihood of stopping the water supply, elementary actions can be performed that do not require large investments and skilled work.
For the southern regions, where the depth of the water supply is small, it is enough to dig pipes in the fall, fill them with environmentally friendly insulating material and again dig a trench.
For insulation, you can use leaves, straw, shavings or sawdust. They have low thermal conductivity, but by the next winter they will have time to rot in the ground, so this procedure must be repeated annually.
If, according to calculations, the pipes are located slightly above the level that allows to guarantee the system does not freeze, then instead of deepening the water supply, it is possible to solve the problem by raising the zero isotherm.
There are two ways to do this:
- increase the thickness of the layer of earth, pouring it on top;
- use snow for warming.
In both cases, the center of the land or snow dumping strip is located along the water supply, and its width should be at least two times the depth of the pipes.
Snow is a good natural insulation. Even a 30-centimeter layer of it is able to halve the depth of freezing of the earth
The filling of the land will change the landscape of the site area, and warming with plant and wood waste or snow must be carried out constantly. Therefore, for a long-term and reliable solution to the problem of water supply insulation, special developed materials are used.
The water supply system laid below the seasonal freezing point in the region is insulated only in the section passing through the thickness of the rocks freezing in winter. Thermal insulation is arranged from the specified level to the input of the pipe into the house.
If the water supply runs into the house through an unheated basement arranged below the freezing depth, then insulation is carried out within the basement. Then a wooden box is arranged around the water supply section, and the space between it and the pipe is filled with sawdust or basalt wool.
Types and forms of materials
To warm the water supply, materials are used that are presented in the form of shells - forms that follow the contours of pipes and system nodes. They are made of basalt wool, glass wool, foam, extruded polystyrene foam, polyurethane foam, foam glass.
In the case of using mineral wool and glass wool, a prerequisite for underground installation is the presence of a foil shell. It prevents the insulation from getting wet, due to which the insulation properties of the material are almost destroyed. The shell can be replaced by wrapping pipes with basalt insulation with roofing material.
Due to the ability to freely absorb moisture in the arrangement of underground networks, cotton insulation is not used in the form of mats cut into slabs or rolled into bales without waterproofing external protection.
An exception may be the laying of the pipeline in concrete trays with backfilling of the free space between the tray and the expanded clay pipe or similar material.
The presence of a constructive seam in cylindrical glass wool insulation makes it easy to install the product on the water supply
The heat-insulating shell is a finished workpiece of cylindrical shape, whose inner diameter coincides with the outer diameter of the pipes. Products with a length of 60 cm to 2 meters consist of a single tube with a structural seam, if the insulation material is elastic or from several (most often two) sections. The main advantage of the sectional material for insulation is the ease of installation of the product.
The halves of the relatively thin shell are joined with the edge of the element superimposed on the next element to avoid the formation of unprotected sections of the pipeline. The offset of meter sections, as a rule, is 15-20 cm.
If it is necessary to use a thickened insulation, it is better to choose a shell with a mounting chamfer along the end edge. The second option for providing tight joints is a certain displacement of the parts of the shell relative to each other.
To form durable shell joints and increase the rigidity of the heat-insulating structure, parts of the shell are recommended to be slightly shifted relative to each other
When attaching parts of the shell, plumbing tape is used. Adjacency protection of pipe bends, turns and other system nodes occurs with the help of special shaped forms.
Thermal insulation paint and polyurethane foam spraying
One of the additional solutions to prevent freezing of the external water supply line located in the ground is liquid or spray thermal insulation. This method allows you to reliably, without seams and cold bridges to protect areas with complex geometry, for which it is difficult to use standard materials for insulation.
Polyurethane foam has a liquid consistency and is applied to insulated objects by spraying. Having one of the best indicators of thermal conductivity, as well as a number of other positive properties, this material is characterized by a significant minus: for its application, special equipment is needed.
Polyurethane foam is one of the best heaters for underground water supply. However, its spraying is a technologically complex process requiring expensive equipment, safety precautions and professional skills.
It is not difficult to find companies that are engaged in thermal insulation using polyurethane foam, as it is actively used at various facilities. However, all service providers have restrictions on the minimum spraying area, so it is unlikely to be able to find an affordable option solely for the sake of 10 or 20 meters of the pipeline.
Special heat-insulating paint for pipe insulation similar to polyurethane foam can be applied by spraying. It is sold in cans, so this procedure is easy to perform on your own. There is also an option in liquid form, which allows you to paint the elements of the water supply with an ordinary paint brush.
Image Gallery
Photo from
The composition of liquid ceramic thermal insulation
Application by spray gun
Pipes in an unheated basement
Thermal insulation paint contains additives in the form of ceramic microspheres, foam glass or perlite. The thermal conductivity of this material is quite low, but due to the thin coating layer, it alone may not be enough to solve the problem of warming a section of a water supply system crossing the thickness of freezing soils.
Due to the high cost, applying a thick layer of thermal insulation paint is expensive. Therefore, its use for warming is justified only in areas with complex geometry or in places of possible occurrence of cold bridges.
The use of heat-insulating paint is justified both for outdoor and for sections of a complex water supply system located in an unheated basement or in the ground
However, in the case of the use of steel pipes, the use of paint along the entire length together with other insulation may be advisable for another reason. The presence in the composition of the porous material leads to a high rate of adhesion, eliminating the possibility of the formation of external corrosion, which is important for metal structures located in the ground.
Complete solutions
The problem of freezing a street branch of a water supply system is very relevant. Demand creates supply and, therefore, there are a large number of ready-made integrated solutions on the market in the form of heat-insulated pipes and connecting elements. They are pipelines surrounded by a heater, which is enclosed in a solid or flexible shell.
Image Gallery
Photo from
Pre-insulated pipes for communications
The device of pipelines of any complexity
Knots and connections in pipeline systems
Scope of use of pre-insulated pipes
There are both single-pipe and two-pipe options for a ready-made solution for insulation of the outer pipe lining.For ordinary cold water, structures containing plastic pipes are the best option. They are cheaper than a metal counterpart and have a high installation speed.
HDPE insulated pipes are delivered in bays up to 200 meters long. The laying of water supply systems based on them can be performed with a minimum number of joints.
If corrugated material is used as the outer shell, it is possible to conduct a pipeline without the use of corner joints. This is possible due to the simplicity of making small radius bends of all parts of the kit.
There are ready-made integrated solutions for insulation of water supply systems. Available with one or two pipes of different diameters
Insulation protection from negative factors
Protection against freezing of a water pipe located in the ground has its own specifics. The material should not completely or partially lose its heat-insulating properties under the influence of external factors.
Re-insulating or repairing the outer layers requires expensive and time-consuming excavation work, so you must immediately take care to maintain the integrity of the protective structure.
The destructive effects of land and water
The underground water pipe is experiencing soil pressure, so the material used in the insulation can be wrinkled. In this case, its thermal conductivity can significantly increase. To prevent such a development of events, it is necessary to create a solid outer shell using pipes of larger diameter or special trays.
Mineral wool is hygroscopic and can be wrinkled with a little finger effort, so the earth layer compresses the material and it will lose the property of low thermal conductivity
If hygroscopic materials are used as thermal insulation of pipelines, it is necessary to prevent the possibility of the influence of ground water on them, which is always in the ground, regardless of the degree of soil water saturation.
To protect the mineral and glass wool, additional protective equipment is used - plastic pipes of a size larger than water pipes, which simultaneously solves the problem of crushing the insulation.
You can also use the following materials to create a waterproofing sheath:
- rolled aluminum foil;
- reinforced (plumbing) tape;
- roofing material;
- high density plastic film.
Polyfoam, extruded polystyrene foam weakly absorb moisture, but over time, they also become worthless with constant defrosting. Foam glass, polyurethane foam, and heat-insulating paint are not completely susceptible to crushing and moisture.
Protecting objects located in the ground from moisture with the help of roofing material - a long-used, but not the most practical option
Solving the problem of insects and rodents
Another cause of damage to the insulation of the water supply can be rodents and insects. Ants gnaw through numerous moves in an attractive thermal insulation for them, and mice use it to build a nest. These actions expose parts of the pipes, which negatively affects the quality of insulation.
Neither insects nor mice can spoil polyurethane foam, foamglass, but they perfectly deal with basalt cotton wool. It and similar materials for external insulation of water pipes must be protected from rodents if they are located at a depth of less than 2 meters. Earth ants do not penetrate below 1 meter, while forest ants build a large anthill, the aerial part of which cannot be overlooked.
To protect against rodents, you can wrap the insulation with a metal mesh. To prevent access not only to mice, but also to ants, it is necessary to wrap the material with aluminum foil reinforced with adhesive tape or use plastic pipes or trays of any shape as the outer shell.
A shell made of polyurethane foam or foam glass withstands soil pressure, the effects of moisture in the ground, and also can not be spoiled by rodents and insects
Heated external water supply systems
If we consider any system, then warming is just a way to increase the time to reduce its temperature to a value corresponding to the environment. Therefore, sometimes you have to resort to another option to prevent freezing of the water supply - heating.
The water supply is heated by external energy sources and there are several ways to organize this process.
Water circulation
The simplest source of additional thermal energy is water, the temperature of which is higher than in the insulated section of the water supply. If warmer water constantly replaces chilled water, then the system does not freeze. For this reason, the “ajar tap” method works when a slow but constant movement of fluid through pipes is organized.
For cold water supply of individual housing, it is possible to organize periodic replacement of water in the outer branch with a warmer one. In the case of supply from the main water supply system, it is often necessary to drain in small portions, which ensures fluid replacement.
It is rational for this to use a special tank located in the house, which also functions as a sump, from which water can subsequently be taken for its own needs.
Draining water to prevent freezing may be at a time when it is not necessary. Use it later will allow the storage tank
If the supply is organized from wells, in which the water temperature is usually from 7 to 10 degrees Celsius, it is necessary to turn on the pump more often. For storage of water, you can also use a conventional storage tank or tank.
Using the second pipe and a three-way valve, it is possible to organize the circulation of liquid with its discharge back to the well. At one time, it is enough to pump 1.5 - 2 volumes of a section of water supply located in the ground between the head of the well and the entrance to the house.
In the case of water intake from the well, there is also the option of draining it by gravity back after the pump stops. This method is inappropriate to use in the case of metal elements of the water supply system. The constant change of fluid and air leads to intense corrosion of the inner surface of the pipes and the deterioration of water quality.
In autonomous water supply systems based on boreholes, a warming of the water source is required in the same way as thermal insulation of the pipeline itself. We recommend that you read the article on the methods of thermal insulation of water wells.
If there is a possibility of prolonged downtime of water and, as a consequence, its freezing, then despite the warming, it is necessary to apply other methods of heating.
Using an electric cable
Most often, electric cables are used as an additional heat source for an individual water supply system located in the ground. They can be placed both inside the pipe supplying water and on its outer surface. The principle of heating is to convert electrical energy into heat.
An electric cable heats the elements of the water supply, from which heat is transferred to the water. External insulation prevents heat from entering the ground
Cables located inside the system have higher efficiency than external cables due to direct heating of the liquid.
The disadvantages of this option for the location of the cable include:
- higher price per linear meter due to environmental requirements;
- the complexity, and sometimes the inability to conduct through curved sections of the water supply;
- Strong recommendations by specialists to connect through an RCD, despite certificates of compliance with the increased requirements of electrical protection.
Installation of both options is approximately equal in complexity. The cable passing inside the pipe is sold complete with a special terminal sleeve. Its connection is made through a standard tee. The outer cable is fastened with aluminum tape, and an insulating shell is necessarily applied on top so that the energy does not go into the ground.
Image Gallery
Photo from
Mounting the heating cable outside the pipe
The specifics of installing the cable inside the pipe
Water supply insulation in open areas
Laying pipes with cable in the ground
Complete with a resistive cable that emits a constant amount of heat, it is better to use a thermostat to automatically turn the heating on and off to save energy. When using a self-regulating version of the cable, it is necessary to choose its parameters correctly, then there is no need to use a temperature regulating device.
There are ready-made integrated solutions that, in addition to a water pipe, insulation and a rigid waterproof shell, have an integrated heating cable. Such kits significantly reduce the installation time of the system, however, the purchase of all the elements separately will be much cheaper.
Ready-made solutions for underground water pipelines may include a heating cable, which virtually eliminates the possibility of freezing the system
A heating cable can be used to heat both a part of the system and a completely external section of the pipeline, which makes it unnecessary to lay the line below the level of seasonal freezing of soils.
The use of warm air
Another effective way to protect the water pipe laid in the ground from freezing is to heat it with warm air from the house. There are two options - with natural and forced air circulation and both require the installation of an additional closed tray or pipe of a larger diameter.
In the case of natural air circulation, they put a pipe on the water supply and insulate it from the outside. It has access to a warm room and, therefore, there is a slow circulation of air enveloping the water supply system with the transfer of heat to it from the basement or first floor of the house.
In the second case, along the entire length of the water supply, two channels (p-shaped profiles) are fastened along which air passes. They are wrapped with insulation and covered with an outer pipe to prevent the ground and insulation from being crushed by the ground.
At the end of the heated segment, these profiles are connected, thus obtaining a closed system with indoor input and output. Air supply is forced by means of a hairdryer.
Schematic representation of the insulated structure of the underground water supply system in case it is heated with warm air from the room. The forced circulation option includes the use of a hairdryer directing a stream of air into one of the profiles
Video # 1. Laying a pipeline in the ground from the well to the house with its insulation and the nuance of freezing around the foundation:
Video # 2. Warming of a water supply system based on a plastic pipe and a method of warming a knee with a larger diameter cylinder:
Video # 3. Detailed instructions for attaching an external heating cable, taking into account the correct bypass of fasteners and taps:
High-quality insulation or heating of the water supply system located underground, will ensure its uninterrupted supply in the winter. In case of neglect of the rules of installation and protection from the cold, a complicated defrosting procedure and expensive repair of the water supply system can follow.
Want to talk about your own experience in installing thermal insulation for water pipes in a suburban area? Would you like to share useful information with us and site visitors? Please write comments in the block below, ask questions, post a photo on the topic.